Scheduled Electrical Testing and Everyday Electrical Work, From One Team
Commercial electrical work is different from a house call. A strata building, care provider, child care centre, office or shop has shared switchboards and common areas, equipment that has to be tested on a schedule, and an owner, committee or property manager who needs the records to show it was done.
Infinite Maintenance Solutions is a commercial electrician on the Gold Coast and Tweed Heads. We do the scheduled testing, the everyday electrical work and the upgrades with the same in-house team, so one call covers the lot.
Our electricians are licensed in Queensland and New South Wales, so properties on both sides of the border are covered by the same team.
Licensed Electricians | Same Day Response | All Work Fully Guaranteed
Electrical Testing for Strata and Commercial Sites
Scheduled testing for strata buildings, care providers and commercial sites.
Emergency and Exit Lighting Testing
Emergency and exit lights keep the way out visible when the power fails. Testing proves each fitting switches on and that its battery lasts long enough to get people out. Our electricians install and test emergency and exit lighting.
Read more
Exit signs and emergency lights run on a small battery that charges while the power is on. A fitting can look fine and still fail when it’s needed, because the battery has worn out or its charger has stopped working. A discharge test runs the fitting on its battery, so any light that goes dark early shows up before it matters.
These fittings sit in stairwells, corridors, car parks and exits across strata buildings, offices, shops, child care centres and care facilities. If a fitting fails, it needs repair or replacement.
Safety Switch Testing
A safety switch cuts the power in a fraction of a second when it detects a leak of current, which protects people from electric shock and helps prevent electrical fires. We install and test safety switches.
Read more
A safety switch turns off the electricity within milliseconds of a fault. Pressing the test button should trip it, and if it doesn’t, the switch is faulty and a licensed electrician needs to replace it. Queensland’s Electrical Safety Office advises testing safety switches with the test button every three months, and the NSW Government advises testing them twice a year.
In Queensland, owners of domestic rental accommodation must have a safety switch on all power point circuits, and owners who don’t can be fined up to 1,500 dollars.
Test and Tag
Test and tag is the inspection, testing and tagging of portable electrical equipment that plugs into a power outlet, like leads, power boards, kettles and tools. We test and tag appliances.
Read more
How often equipment needs testing depends on the workplace and the risks. SafeWork NSW explains that the Australian Standard AS/NZS 3760 sets out the inspection, testing and tagging methods and the frequency. Child care centres, offices, shops and any tenancy with portable equipment all use it.
Our Signature Streamline Service
From booking to job done, our easy & reliable system ensures a stress-free, organised and quality experience every time.
​
Step 1 – Book A Job
Bookings made within 24hrs
Same day response when required
Guaranteed schedule updates along the way
Step 2 – Stay Connected
Fully customisable service
Easy connection between client and site contacts
Schedule alerts reminders

What You Get With Every Job
Maintenance off your desk, with everything in one place.
- A report with photos from site when each job is finished
- Your own login to see every current and completed job, quote, form and invoice
- We text tenants available appointment times, so they can confirm or ask for another time
- Same day response when the job needs it, during business hours
Strata Electrician and Everyday Commercial Electrical Work
Fault finding, repairs and upgrades by the same team that does the testing.
Strata Electrician
A strata building has electricity on two sides of the line: common property like lighting, power and shared switchboards, and the individual lots. We do common property and lot work for committees, strata managers and owners, on one account.
Read more
Under a standard format plan in Queensland, the body corporate looks after wiring on common property, in a boundary structure or servicing more than one lot, and lot owners look after wiring that only services their lot. Knowing which side a fault sits on decides who pays.
Commercial Tenancies
Shops, offices and tenancies, across plumbing, electrical and air conditioning. When something fails in a tenancy, the business feels it straight away, so one team that covers every trade keeps the fix simple.
Switchboard Upgrades and Electrical Safety Inspections
The switchboard is the heart of a building’s electrical system. Upgrades and safety inspections keep your electrical system compliant and safe, and find hazards before they turn into costly problems.
Read more
Older boards can lack safety switches or struggle with the load of modern equipment, and a routine inspection is the cheapest way to find that out.
Lighting and Data Cabling
Indoor feature lighting, outdoor security lights and LED upgrades, plus data and communication cabling for internet, phone and other needs, all installed by licensed electricians.
Read more
LED lighting upgrades can cut running costs, and cabling is easiest to run when it’s planned alongside other electrical work.
Strata Electrical: Who Looks After What?
Under a standard format plan in Queensland, the body corporate maintains common property, including utility infrastructure such as wiring on common property, in a boundary structure or servicing more than one lot.
Lot owners maintain wiring that only services their lot, along with the inside of their building and its fixtures and fittings.
We work for both. Committees and strata managers use one account for common property work, and owners and their property managers book lot jobs the same way.
Building format plans split responsibilities differently.
Safety Switches: Queensland and New South Wales
The two states advise different testing rhythms. In Queensland, the Electrical Safety Office advises testing safety switches every three months with the test button, and requires owners of domestic rental accommodation to have a safety switch on all power point circuits. In New South Wales, the NSW Government advises testing them twice a year, and a working safety switch is part of the condition report at the start of every tenancy. A faulty one found during a tenancy counts as an urgent repair.
Other Services for Business Sites
One in-house team and one account across every trade.
Commercial Plumbing
Backflow testing, thermostatic mixing valve testing, jet rodding and CCTV drain inspections, and everyday plumbing for strata buildings, rentals and commercial sites, by our own licensed plumbers.
Smoke Alarm Compliance
Smoke alarm testing and compliance for rentals under the Queensland and New South Wales rules, with an annual plan that includes unlimited visits for lease renewals and nuisance alarms.
Commercial Air Conditioning
Split system installation, servicing and repairs by ARCtick licensed technicians, for offices, shops, rentals and strata buildings. We don’t install ducted systems.
Strata and Property Maintenance
Plumbing, electrical, air conditioning, handyman and smoke alarm compliance for property managers, real estate agencies, strata, commercial sites and care providers, on one account.
Request Rates
Managing a strata building, care provider or commercial site? Tell us about it and we’ll send through our rates and how the account works.
Prefer to talk? Call us on 1300 707 370, Monday to Friday, 7am to 4pm.
Already set up with us?
Book a job or log in to see your jobs.
Commercial Electrical Questions
How often should safety switches be tested?
In Queensland, the Electrical Safety Office advises testing safety switches every three months using the test button. The NSW Government advises testing them twice a year. If a safety switch doesn’t trip when tested, it’s faulty and needs replacing by a licensed electrician. We install and test safety switches.
Do rental properties in Queensland need safety switches?
Yes. Owners of domestic rental accommodation in Queensland must have a safety switch installed on all power point circuits, and owners who don’t can be fined up to 1,500 dollars. We install and test safety switches.
What is a discharge test for emergency lighting?
A discharge test runs each emergency light on its own battery instead of the mains, to check it stays lit for long enough to get people out. Our electricians install and test emergency and exit lighting.
What does test and tag cover?
Test and tag covers portable electrical equipment that plugs into a power outlet. How often it’s needed depends on the workplace and the risks. We test and tag appliances.
Do you work on both sides of the border?
Yes. Our electricians are licensed in Queensland and New South Wales, so properties on both sides of the border are covered by the same team.
Do you do strata and body corporate work?
Yes. We look after body corporate and strata properties across the Southern Gold Coast and Northern New South Wales, covering plumbing, electrical, air conditioning, handyman and smoke alarm work with one team.
Do you service commercial properties, like shops and offices?
Yes. We work on commercial properties as well as homes, across plumbing, electrical and air conditioning.
Do you send photos and a job report after each visit?
Yes. Our technicians send a report with photos straight from site when the job is finished, and you can see it anytime in your online login, along with the quote and invoice.
Can you set up scheduled preventative maintenance for our properties?
Yes. We can build a maintenance schedule for a property or a portfolio, covering plumbing checks, electrical safety inspections, air conditioning servicing and smoke alarm compliance. It cuts down on surprise repairs and tenant complaints, and suits property managers, strata buildings and busy holiday rentals.
Our Services
Sources